Validation of a novel Multi-Gas sensor for volcanic HCl alongside H2S and SO2 at Mt. Etna - INSU - Institut national des sciences de l'Univers
Article Dans Une Revue Bulletin of Volcanology Année : 2017

Validation of a novel Multi-Gas sensor for volcanic HCl alongside H2S and SO2 at Mt. Etna

Damien Vignelles
  • Fonction : Auteur
  • PersonId : 964387
R. Baron

Résumé

Volcanic gas emission measurements inform predictions of hazard and atmospheric impacts. For these measurements, Multi-Gas sensors provide low-cost in situ monitoring of gas composition but to date have lacked the ability to detect halogens. Here, two Multi-Gas instruments characterized passive outgassing emissions from Mt. Etna’s (Italy) three summit craters, Voragine (VOR), North-east Crater (NEC) and Bocca Nuova (BN) on 2 October 2013. Signal processing (Sensor Response Model, SRM) approaches are used to analyse H2S/SO2 and HCl/SO2 ratios. A new ability to monitor volcanic HCl using miniature electrochemical sensors is here demonstrated. A “direct-exposure” Multi-Gas instrument contained SO2, H2S and HCl sensors, whose sensitivities, cross-sensitivities and response times were characterized by laboratory calibration. SRM analysis of the field data yields H2S/SO2 and HCl/SO2 molar ratios, finding H2S/SO2 = 0.02 (0.01–0.03), with distinct HCl/SO2 for the VOR, NEC and BN crater emissions of 0.41 (0.38–0.43), 0.58 (0.54–0.60) and 0.20 (0.17–0.33). A second Multi-Gas instrument provided CO2/SO2 and H2O/SO2 and enabled cross-comparison of SO2. The Multi-Gas-measured SO2-HCl-H2S-CO2-H2O compositions provide insights into volcanic outgassing. H2S/SO2 ratios indicate gas equilibration at slightly below magmatic temperatures, assuming that the magmatic redox state is preserved. Low SO2/HCl alongside low CO2/SO2 indicates a partially outgassed magma source. We highlight the potential for low-cost HCl sensing of H2S-poor HCl-rich volcanic emissions elsewhere. Further tests are needed for H2S-rich plumes and for long-term monitoring. Our study brings two new advances to volcano hazard monitoring: real-time in situ measurement of HCl and improved Multi-Gas SRM measurements of gas ratios.
Fichier principal
Vignette du fichier
art_10.1007_s00445-017-1114-z.pdf (2.36 Mo) Télécharger le fichier
Origine Publication financée par une institution
Loading...

Dates et versions

insu-01522753 , version 1 (15-05-2017)

Identifiants

Citer

Tjarda J. Roberts, T Lurton, G. Giudice, Marco Liuzzo, A. Aiuppa, et al.. Validation of a novel Multi-Gas sensor for volcanic HCl alongside H2S and SO2 at Mt. Etna. Bulletin of Volcanology, 2017, 79 (36), 14 p. ⟨10.1007/s00445-017-1114-z⟩. ⟨insu-01522753⟩
398 Consultations
206 Téléchargements

Altmetric

Partager

More