Quantifying diffuse and discrete venting at the Tour Eiffel vent site, Lucky Strike hydrothermal field
Résumé
The relative heat carried by diffuse versus discrete venting of hydrothermal fluids at mid-ocean ridges is poorly constrained and likely varies among vent sites. Estimates of the proportion of heat carried by diffuse flow range from 0% to 100% of the total axial heat flux. Here, we present an approach that integrates imagery, video, and temperature measurements to accurately estimate this partitioning at a single vent site, Tour Eiffel in the Lucky Strike hydrothermal field along the Mid‐Atlantic Ridge. Fluid temperatures, photographic mosaics of the vent site, and video sequences of fluid flow were acquired during the Bathyluck'09 cruise (Fall, 2009) and the Momarsat'10 cruise (Summer, 2010) to the Lucky Strike hydrothermal field by the ROV Victor6000 aboard the French research vessel the “Pourquoi Pas”? (IFREMER, France). We use two optical methods to calculate the velocities of imaged hydrothermal fluids: (1) for diffuse venting, Diffuse Flow Velocimetry tracks the displacement of refractive index anomalies through time, and (2) for discrete jets, Particle Image Velocimetry tracks eddies by cross‐correlation of pixel intensities between subsequent images. To circumvent video blurring associated with rapid velocities at vent orifices, exit velocities at discrete vents are calculated from the best fit of the observed velocity field to a model of a steady state turbulent plume where we vary the model vent radius and fluid exit velocity. Our results yield vertical velocities of diffuse effluent between 0.9 cm s−1 and 11.1 cm s−1 for fluid temperatures between 3°C and 33.5°C above that of ambient seawater, and exit velocities of discrete jets between 22 cm s−1 and 119 cm s−1 for fluid temperatures between 200°C and 301°C above ambient seawater. Using the calculated fluid velocities, temperature measurements, and photo mosaics of the actively venting areas, we calculate a heat flux due to diffuse venting from thin fractures of 3.15 ± 2.22 MW, discrete venting of 1.07 ± 0.66 MW, and, by incorporating previous estimates of diffuse heat flux density from Tour Eiffel, diffuse flux from the main sulfide mound of ∼15.6 MW. We estimate that the total integrated heat flux from the Tour Eiffel site is 19.82 ± 2.88 MW and that the ratio of diffuse to discrete heat flux is ∼18. We discuss the implication of these results for the characterization of different vent sites within Lucky Strike and in the context of a compilation of all available measurements of the ratio of diffuse to discrete heat flux.
Fichier principal
Mittelstaedt_et_al-2012-Geochemistry%2C_Geophysics%2C_Geosystems.pdf (1.83 Mo)
Télécharger le fichier
Origine | Fichiers éditeurs autorisés sur une archive ouverte |
---|
Loading...